Contact us Heritage collections Image license terms
HOME ACL Associates Technology Literature Applications Society Software revisited
Further reading □ Overview1 Logging System2 Console Teletype3 June-July 19754 Settings5 Maintenance6 Errors7 Simulator8 Copy Tape9 Defaults10 Dumping11 Logging12 Aug-Oct 197513 360 Graphics14 Print, Oxford15 Print, RL16 Minutes Nov 1976
ACD C&A INF CCD CISD Archives Contact us Heritage archives Image license terms

Search

   
ACLLiteratureProgress ReportsFR80 Operations :: FR80 Operations
ACLLiteratureProgress ReportsFR80 Operations :: FR80 Operations
ACL ACD C&A INF CCD CISD Archives
Further reading

Overview
1 Logging System
2 Console Teletype
3 June-July 1975
4 Settings
5 Maintenance
6 Errors
7 Simulator
8 Copy Tape
9 Defaults
10 Dumping
11 Logging
12 Aug-Oct 1975
13 360 Graphics
14 Print, Oxford
15 Print, RL
16 Minutes Nov 1976

Setting Intensity and Focus

R Brandwood

23 September 1975

Experience has shown that there is interaction between the FOCUS, QUAD, and IN PHASE which can cause one of the other settings to have no swing at all.

Setting INTENSITY and FOCUS should be accomplished as follows:

1. Load a film-making program and type FOCUS/255. This will cause focus image to appear on both monitor screen and PLS.

2. At Light Source Control Panel, select correct MULTIPLIER setting, then adjust the INTENSITY until the correct reading is obtained.

3. The actual focus is accomplished by null.ng the FOCUS, QUAD and IN PHASE.

Turn each knob so that it causes the meter needle to move down on the scale. When the needle reaches a certain point it will start back up again. Adjust the knob so that the needle is positioned at the lowest point.

Perform this adjustment with each of the knobs until the needle is nulled as much as possible. Locking the knobs will prevent them from being accidentally moved later on.

If trouble is experienced achieving swing on the needle, reset the knobs to mid-position (500) a~d start again.

4. Re-adjust the INTENSITY knob until the desired reading is obtained.

5. Return control to MONITOR by typing CTRLI on the teletype keyboard.

6. Set CONTRAST by typing FOCUS/0 and adjusting CONTRAST knob to desired level.

7. CONTRAST and INTENSITY are interactive and may require several attempts before the correct settings are obtained.